Design
EN 837-1
Nominal size in mm
63, 80, 100
Accuracy class
NS 63, 80: 1.6 NS 100: 1.0
Scale ranges
0 ... 0.6 to 0 ... 1,000 bar or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation
NS 63, 80:
Steady: 3/4 x full scale value
Fluctuating: 2/3 x full scale value
Short time: Full scale value
NS 100:
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.3 x full scale value
Permissible temperature
Ambient: -20 … +60 °C
Medium: +60 °C maximum
Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of the span
Ingress protection
IP 65 per EN 60529 / lEC 60529