What is a secondary containment chamber?
The secondary containment chamber is a sealed chamber (neck tube) between the primary seal weld and secondary seal weld that contains an instrument connection. In the event of a primary weld failure, the secondary containment chamber would pressure ...
moreDoes the FLEX-R® (model TC96-R) include a secondary seal?
Yes, FLEX-R® assemblies can have a primary seal weld and a secondary seal weld from the thermocouple to the flange assembly at the face of the flange, not on a single disk, and again after the secondary containment chamber.
Can the FLEX-R® be installed in the reactor in the horizontal position?