What is a secondary containment chamber?
The secondary containment chamber is a sealed chamber (neck tube) between the primary seal weld and secondary seal weld that contains an instrument connection. In the event of a primary weld failure, the secondary containment chamber would pressure ...
moreCan the FLEX-R® be installed in the reactor in the horizontal position?
Yes, the FLEX-R® can be installed in any position. However, care should be taken to ensure the internal structures are tightly secured in their proper position.
What design verification is provided with the FLEX-R® flange assembly?
ASME code calculations are performed to determine the suitability and sizing of the primary connection, the secondary connection, and the secondary containment chamber. All welds are liquid dye penetrant tested (LPI). The assembly receives an inter ...
more