Every measuring instrument is subject to ageing as a result of mechanical, chemical or thermal stresses and thus delivers measured values that change over time. This cannot be prevented, but it can be detected in good time by calibration. Use our calibration service for your pressure measuring instruments in order to minimise safety risks.
Our skilled team can calibrate your equipment in our laboratory or on-site, minimizing disruption to your operations. We handle a wide range of manufacturers and models, using regularly certified NATA equipment to ensure you are receiving the most accurate results.
Trust WIKA Australia for expert calibration services that keep your operations running smoothly and efficiently.
The origin of WIKA's calibration laboratories date back to 1963. WIKA's ISO 17025 National Association of Testing Authorities (NATA) accredited laboratories, ensure rigorous quality and accuracy for all customer calibration needs, offering high-accuracy calibration technologies specifically for pressure measuring instruments.
Your benefits
- Many years of competence
- Service and replacement instrument from one source
- Fast lead times
- Modern calibration laboratory
- Qualitative advice
- WIKA Calibration software
- On-site calibration
Special features
- NATA accreditation per DIN EN ISO / IEC 17025
- Type of certificate: 3.1 inspection certificate or NATA calibration certificate
If legal regulations require a verification for your measuring instruments, we will be pleased to carry this out under the professional supervision of a calibration officer.
Calibratable measuring devices
We calibrate and adjust, independently of the manufacturer:
- All pressure measuring instruments for negative and positive pressure, differential pressure incl. differential pressure under static pressure and absolute pressure
- Dial pressure gauges
- Electrical pressure measuring instruments such as transducers, transmitters and pressure sensors
- Analogue differential pressure gauges
- Pressure switches
- Liquid-column pressure gauges / U-tube pressure gauges
- Inclined tube manometers
- Digital manometers
- Pressure calibrators
- Dead-weight testers / pressure balances
- Pressure controllers
- Vacuum gauges
- Absolute pressure sensors
- Differential pressure sensors
- Test gauges
- Chart recorders
- Backflow test kits
Sydney laboratory
Digital pressure gauges; Mechanical pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges
Absolute pressure |
Uncertainty (% of reading) | Pressure range |
0.008 % or 6 Pa (whichever is greater) | 40 Pa to 120 Mpa |
|
Gauge pressure |
Uncertainty (% of reading) | Pressure range |
0.008 % or 0.8 Pa (whichever is greater) | -100 kPa to 100 kPa |
0.006 % | 100 kPa to 5,000 kPa |
0.008 % | 5 MPa to 20 Mpa |
0.007 % | 20 MPa to 120 Mpa |
0.080 % | 120 MPa to 260 Mpa |
0.100 % | 260 MPa to 350 Mpa |
0.1 % (on-site) | -100 kPa to 120 Mpa |
0.2 % (on-site) | 120 MPa to 350 Mpa |
Pressure calibrators - Non-dead weight
Absolute pressure |
Uncertainty (% of reading) | Pressure range |
0.008 % or 6 Pa (whichever is greater) | 40 Pa to 120 Mpa |
|
Gauge pressure |
Uncertainty (% of reading) | Pressure range |
0.008 % or 0.8 Pa (whichever is greater) | -100 kPa to 100 kPa |
0.006 % | 100 kPa to 5,000 kPa |
0.008 % | 5 MPa to 20 Mpa |
0.007 % | 20 MPa to 120 Mpa |
0.080 % | 120 MPa to 260 Mpa |
0.100 % | 260 MPa to 350 Mpa |
0.2 % (on-site) | -100 KPa to 350 Mpa |
Manometers
Gauge pressure |
Uncertainty (% of reading) | Pressure range |
0.008 % or 0.8 Pa (whichever is greater) | -100 kPa to 210 kPa |
Perth laboratory
Digital pressure gauges; Mechanical pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges
Absolute pressure |
Uncertainty (% of reading) | Pressure range |
0.25 kPa | 1.3 kPa to 110 kPa |
0.150 % | 110 kPa to 200 kPa |
0.100 % | 200 kPa to 110 Mpa |
|
Gauge pressure |
Uncertainty (% of reading) | Pressure range |
0.015 % or 30 Pa (whichever is greater) | -100 kPa to 110 Mpa |
0.15 % (on-site) | 10 kPa to 100 kPa |
0.1 % (on-site) | 100 kPa to 110 Mpa |
Pressure calibrators - Non-dead weight
Absolute pressure |
Uncertainty (% of reading) | Pressure range |
0.008 % or 6 Pa (whichever is greater) | 40 Pa to 120 Mpa |
|
Gauge pressure |
Uncertainty (% of reading) | Pressure range |
0.008 % or 0.8 Pa (whichever is greater) | -100 kPa to 100 kPa |
0.006 % | 100 kPa to 5,000 kPa |
0.008 % | 5 MPa to 20 Mpa |
0.007 % | 20 MPa to 120 Mpa |
0.080 % | 120 MPa to 260 Mpa |
0.100 % | 260 MPa to 350 Mpa |
0.2 % (on-site) | -100 KPa to 350 Mpa |
Brisbane laboratory
Digital pressure gauges; Mechanical pressure gauges; Vacuum gauges
Gauge pressure |
Uncertainty (% of reading) | Pressure range |
0.2 % or 200 Pa (whichever is higher) | -100 kPa to 500 kPa |
0.300 % | 500 kPa to 700 kPa |
0.100 % | 700 kPa to 15,000 kPa |
0.030 % | 15,000 kPa to 60,000 kPa |
0.050 % | 60,000 kPa to 120,000 kPa |
** all of above includes on-site |
Calibration always results in an interruption of processes. Not so with the on-site service from WIKA! In order to have the least possible impact on the production process, we also calibrate indispensable measuring devices at your site, directly in the plant.
Your benefits
- No freight charges
- Small repairs are possible
- No transport risks
- Trained personnel
- Calibration of a large number of items in the shortest time
- Minimum production downtime
- IEC 17025 / NATA accredited
Our range of services
- Measuring ranges: -100 kPa to 350 MPa
- Equipment accuracies as low as 0.1 % of reading
- Service areas: Australia
- Type of certificate: 3.1 inspection certificate, NATA calibration certificate
- Services: Calibration, adjustment and repair